东莞市贡福电子有限公司
电话:0769-82391938
0769-81100206
传真:0769-82391939
地址:东莞市寮步凫山星锐工业园B栋3楼
吕先生:15622511589
小吕:15622511110
陈先生:18922960825
江小姐:18922960826
E-mail:lvbin@fuse168.com
E-mail:gf@gfefuse.cn
E-mail:sales@gfefuse.cn
E-mail:jsr@gfefuse.cn
产品展示当前位置:首页 > 产品展示
1.Dimensions (mm)
2.Specifications
v Product Features
v Compact design, suitable for high current applications.
v Rated DC voltage of 150 volts
v Shell material: high-temperature PPS and ceramic
v The product complies with UL248-13 standard
v High current wire protection
v Vehicle distribution (electric motorcycles, new energy trams, charging supporting systems)
v Material processing system
v Unmanned aerial vehicle power distribution protection
v All supercapacitor and battery systems (energy storage protection system)
v Operating temperature -40 ° C to+125 ° C
3. Time-Current Characteristics
|
% of Rating |
Opening Time Min / Max |
|
100A - 700A |
|
|
100 |
4H / ∞ |
|
300 |
~/10S |
4.Product specifications
|
Part Number |
Rating Current(A) |
Pre-arcing I²t(A²s) |
Arcing I²t(A²s) |
Total Clearing I²t(A²s) |
|
ANL-B150B100SF51 |
100A |
520 |
260 |
780 |
|
ANL-B150B150SF51 |
150A |
980 |
400 |
1380 |
|
ANL-B150B200SF51 |
200A |
1650 |
620 |
2270 |
|
ANL-B150B250SF51 |
250A |
2600 |
950 |
3550 |
|
ANL-B150B300SF51 |
300A |
3750 |
1400 |
5150 |
|
ANL-B150B350SF51 |
350A |
5100 |
1900 |
7000 |
|
ANL-B150B400SF51 |
400A |
6800 |
2550 |
9350 |
|
ANL-B150B450SF51 |
450A |
8250 |
3225 |
11475 |
|
ANL-B150B500SF51 |
500A |
10800 |
4000 |
14800 |
|
ANL-B150B550SF51 |
550A |
13100 |
4850 |
17950 |
|
ANL-B150B600SF51 |
600A |
15600 |
5700 |
21300 |
|
ANL-B150B650SF51 |
650A |
18250 |
6550 |
24800 |
|
ANL-B150B700SF51 |
700A |
21000 |
7400 |
28400 |
1. With a short-circuit current of 20kA and a relatively high interruption current, the melting and arcing energy is reduced simultaneously, resulting in a faster breaking speed and less impact on power devices.
2. The overload operating threshold and voltage drop remain unchanged, and the long-term current carrying capacity is not affected by the short circuit level.
3. This breakout specification meets the protection requirements of conventional low-voltage DC busbars, energy storage auxiliary circuits, and industrial control DC equipment.
4. The system short-circuit current is stable within 20kA, and this set of parameters can be directly used for device I²t matching verification.
5. It exhibits good arc extinction stability in low-voltage and low-interruption scenarios, and can be normally adapted to circuits with L/R ≤ 25ms.
6. When selecting a device, a protection margin should be reserved, and the total breaking capacity I²t must be less than the withstand limit of the semiconductor device.